Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathtransfer_switch.py
More file actions
executable file
·444 lines (386 loc) · 21.3 KB
/
transfer_switch.py
File metadata and controls
executable file
·444 lines (386 loc) · 21.3 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
#!/usr/bin/env python
# This program integrates an external transfer switch ahead of the single AC input
# of a MultiPlus or Quattro inverter/charger.
#
# When the external transfer switch changes between grid and generator the data for that input must be switched between
# grid and generator settings
#
# These two sets of settings are stored in dbus Settings.
# When the transfer switch digital input changes, this program switches
# the Multiplus settings between these two stored values
# When the user changes the settings, the grid or generator-specific Settings are updated
#
# In order to function, one of the digital inputs must be set to Bilge Pump (NOT bilge alarm) and the custom name changed to 'Transfer Switch'
# This input should be connected to a contact closure on the external transfer switch to indicate
# which of it's sources is switched to its output
#
# For Quattro, the /Settings/TransferSwitch/TransferSwitchOnAc2 tells this program where the transfer switch is connected:
# 0 if connected to AC 1 In
# 1 if connected to AC 2 In
# credit given to Kevin Windrem for the original package, from which this package is based upon.
import platform
import argparse
import logging
import sys
import subprocess
import os
import time
import dbus
from gi.repository import GLib
sys.path.insert(1, "/opt/victronenergy/dbus-systemcalc-py/ext/velib_python")
from vedbus import VeDbusService
from ve_utils import wrap_dbus_value
from settingsdevice import SettingsDevice
# setup logging
logger = logging.getLogger()
for handler in logger.handlers[:]:
logger.removeHandler(handler)
formatter = logging.Formatter('%(asctime)s - %(name)s - %(levelname)s - %(message)s')
console_handler = logging.StreamHandler(sys.stdout)
console_handler.setFormatter(formatter)
logger.addHandler(console_handler)
logger.setLevel(logging.INFO) # Default to DEBUG for better visibility
dbusSettingsPath = "com.victronenergy.settings"
dbusSystemPath = "com.victronenergy.system"
class Monitor:
def getVeBusObjects (self):
vebusService = ""
# invalidate all local parameters if transfer switch is not active
if not self.transferSwitchActive:
# release generator override if it's still active
try:
if self.remoteGeneratorSelectedItem != None:
self.remoteGeneratorSelectedItem.SetValue (wrap_dbus_value (0))
except:
logging.error ("could not release /Ac/Control/RemoteGeneratorSelected")
pass
self.remoteGeneratorSelectedItem = None
self.remoteGeneratorSelectedLocalValue = -1
self.dbusOk = False
self.numberOfAcInputs = 0
self.acInputTypeObj = None
self.veBusService = ""
self.transferSwitchLocation = 0
# Reset initial found status if transfer switch is not active, assuming no multi/quattro is relevant without it
self.veBusFoundInitially = False
self.loggedVeBusInitialNotFound = False
return
try:
obj = self.theBus.get_object (dbusSystemPath, '/VebusService')
vebusService = obj.GetText ()
except dbus.exceptions.DBusException as e: # Catch specific D-Bus exceptions
if self.dbusOk: # Logs if it disappeared
logging.info ("Multi/Quattro disappeared - /VebusService invalid: %s", e)
elif not self.veBusFoundInitially and not self.loggedVeBusInitialNotFound: # Logs only once if never found initially
logging.warning ("Multi/Quattro (VE.Bus) service not found on startup: %s", e)
self.loggedVeBusInitialNotFound = True # Mark as logged
self.veBusService = ""
self.dbusOk = False
self.numberOfAcInputs = 0
self.acInputTypeObj = None
except Exception as e: # Catch any other unexpected errors
if not self.veBusFoundInitially and not self.loggedVeBusInitialNotFound:
logging.warning("Multi/Quattro (VE.Bus) service not found on startup (unexpected error): %s", e)
self.loggedVeBusInitialNotFound = True
else:
logging.error("An unexpected error occurred while looking for VE.Bus service: %s", e)
self.veBusService = ""
self.dbusOk = False
self.numberOfAcInputs = 0
self.acInputTypeObj = None
if vebusService == "---":
if self.veBusService != "": # Logs if it disappeared
logging.info ("Multi/Quattro disappeared")
elif not self.veBusFoundInitially and not self.loggedVeBusInitialNotFound: # Logs only once if never found initially
logging.warning("Multi/Quattro (VE.Bus) service not found on startup (returned '---')")
self.loggedVeBusInitialNotFound = True # Mark as logged
self.veBusService = ""
self.dbusOk = False
self.numberOfAcInputs = 0
elif self.veBusService == "" or vebusService != self.veBusService:
self.veBusService = vebusService
try:
self.numberOfAcInputs = self.theBus.get_object (vebusService, "/Ac/NumberOfAcInputs").GetValue ()
# Set flag to true if discovery successful, and reset initial not found log flag
self.veBusFoundInitially = True
self.loggedVeBusInitialNotFound = False # Reset if service is now found
except dbus.exceptions.DBusException as e:
logging.error("Failed to get /Ac/NumberOfAcInputs for %s: %s", vebusService, e)
self.numberOfAcInputs = 0
self.veBusFoundInitially = False # Reset if subsequent obj fails
except Exception as e:
logging.error("An unexpected error occurred getting number of AC inputs: %s", e)
self.numberOfAcInputs = 0
self.veBusFoundInitially = False
try:
self.remoteGeneratorSelectedItem = self.theBus.get_object (vebusService,
"/Ac/Control/RemoteGeneratorSelected")
except dbus.exceptions.DBusException as e:
logging.error("Failed to get /Ac/Control/RemoteGeneratorSelected for %s: %s", vebusService, e)
self.remoteGeneratorSelectedItem = None
self.remoteGeneratorSelectedLocalValue = -1
except Exception as e:
logging.error("An unexpected error occurred getting remote generator selected: %s", e)
self.remoteGeneratorSelectedItem = None
self.remoteGeneratorSelectedLocalValue = -1
if self.numberOfAcInputs == 0:
self.dbusOk = False
if self.veBusFoundInitially: # If it was found but inputs couldn't be read
logging.error("VE.Bus service found but no AC inputs or other critical objects. Multi/Quattro might be misconfigured or starting up.")
self.veBusFoundInitially = False # Reset if initial object discovery failed
elif self.numberOfAcInputs == 2:
logging.info ("discovered Quattro at " + vebusService)
elif self.numberOfAcInputs == 1:
logging.info ("discovered Multi at " + vebusService)
try:
self.currentLimitObj = self.theBus.get_object (vebusService, "/Ac/ActiveIn/CurrentLimit")
self.currentLimitIsAdjustableObj = self.theBus.get_object (vebusService, "/Ac/ActiveIn/CurrentLimitIsAdjustable")
except dbus.exceptions.DBusException as e:
logging.error ("current limit dbus setup failed - changes can't be made: %s", e)
self.dbusOk = False
self.veBusFoundInitially = False # Reset if this critical object fails
except Exception as e:
logging.error("An unexpected error occurred setting up current limit objects: %s", e)
self.dbusOk = False
self.veBusFoundInitially = False
# check to see where the transfer switch is connected
if self.numberOfAcInputs == 0:
transferSwitchLocation = 0
elif self.numberOfAcInputs == 1:
transferSwitchLocation = 1
elif self.DbusSettings['transferSwitchOnAc2'] == 1:
transferSwitchLocation = 2
else:
transferSwitchLocation = 1
# if changed, trigger refresh of object pointers
if transferSwitchLocation != self.transferSwitchLocation:
if transferSwitchLocation != 0:
logging.info ("Transfer switch is on AC %d in" % transferSwitchLocation)
self.transferSwitchLocation = transferSwitchLocation
try:
if self.transferSwitchLocation == 2:
self.acInputTypeObj = self.theBus.get_object (dbusSettingsPath, "/Settings/SystemSetup/AcInput2")
else:
self.acInputTypeObj = self.theBus.get_object (dbusSettingsPath, "/Settings/SystemSetup/AcInput1")
self.dbusOk = True
except dbus.exceptions.DBusException as e:
self.dbusOk = False
logging.error ("AC input dbus setup failed - changes can't be made: %s", e)
except Exception as e:
self.dbusOk = False
logging.error("An unexpected error occurred setting up AC input objects: %s", e)
def updateTransferSwitchState (self):
inputValid = False
# If a transfer switch input is currently active, check its name
if self.transferSwitchActive and self.transferSwitchNameObj:
try:
name = self.transferSwitchNameObj.GetValue()
if self.extTransferDigInputName.lower() in name.lower():
# Name matches, now check the state
state = self.transferSwitchStateObj.GetValue()
# Updated state check: 12 or 3 for onGenerator (true), 13 or 2 for not onGenerator (false)
if state in (12, 3): # On generator
inputValid = True
self.onGenerator = True
elif state in (13, 2): # On grid
inputValid = True
self.onGenerator = False
else:
logging.info("Current transfer switch input name '%s' does not match '%s'", name, self.extTransferDigInputName)
except dbus.exceptions.DBusException as e:
logging.error("Error accessing transfer switch D-Bus object: %s", e)
# If there's a D-Bus error, assume the input is no longer valid
inputValid = False
except Exception as e:
logging.error("An unexpected error occurred: %s", e)
inputValid = False
if not inputValid and self.transferSwitchActive:
logging.info ("Transfer switch digital input no longer valid or name mismatch")
self.transferSwitchActive = False
self.transferSwitchNameObj = None # Clear the name object as it's no longer valid
# current digital input (if any) not valid or name mismatch
# search for a new one only every 10 seconds to avoid unnecessary processing
elif not inputValid and self.tsInputSearchDelay >= 10:
newInputService = ""
custom_name = "" # Initialize custom_name here for scope
found = False # Flag to indicate if a service was found
for service in self.theBus.list_names():
# found a digital input service, now check for custom name and valid state
if service.startswith ("com.victronenergy.digitalinput"):
try:
name_obj = self.theBus.get_object(service, '/CustomName')
custom_name_val = name_obj.GetValue() # Use a temporary variable
if self.extTransferDigInputName.lower() in custom_name_val.lower():
state_obj = self.theBus.get_object (service, '/State')
state = state_obj.GetValue()
# found it! Check for new state values
if state in (12, 3) or state in (13, 2):
newInputService = service
custom_name = custom_name_val # Assign to the outer custom_name
self.transferSwitchNameObj = name_obj # Store the name object
self.transferSwitchStateObj = state_obj # Store the state object
found = True
break # Exit loop once found
# ignore errors - continue to check for other services
except dbus.exceptions.DBusException as e:
# This typically means /CustomName or /State doesn't exist for this service
# logging.debug("D-Bus error for service %s: %s", service, e) # Too verbose for regular logging
pass
except Exception as e:
logging.error("An unexpected error occurred while searching for digital inputs: %s", e)
# Process search results
if found:
logging.info ("discovered transfer switch digital input service at %s with custom name '%s'", newInputService, custom_name)
self.transferSwitchActive = True
self.firstSearchDone = True # Mark that a switch has been found
else:
# Log if it was previously active and is no longer found
if self.transferSwitchActive:
logging.info ("Transfer switch digital input service NOT found with matching name")
self.transferSwitchActive = False
# Log a message on the first search attempt if nothing is found
elif not self.firstSearchDone:
logging.warning("No transfer switch digital input found with a custom name matching 'transfer switch'")
self.firstSearchDone = True # Ensure this message is only logged once
if self.transferSwitchActive:
self.tsInputSearchDelay = 0
else:
self.onGenerator = False
# if search delay timer is active, increment it now
if self.tsInputSearchDelay < 10:
self.tsInputSearchDelay += 1
else:
self.tsInputSearchDelay = 0
def transferToGrid (self):
if self.dbusOk:
logging.info ("switching to grid settings")
# save current values for restore when switching back to generator
try:
self.DbusSettings['generatorCurrentLimit'] = self.currentLimitObj.GetValue ()
except:
logging.error ("dbus error generator AC input current limit not saved switching to grid")
try:
self.acInputTypeObj.SetValue (self.DbusSettings['gridInputType'])
except:
logging.error ("dbus error AC input type not changed to grid")
try:
if self.currentLimitIsAdjustableObj.GetValue () == 1:
self.currentLimitObj.SetValue (wrap_dbus_value (self.DbusSettings['gridCurrentLimit']))
else:
logging.warning ("Input current limit not adjustable - not changed")
except:
logging.error ("dbus error AC input current limit not changed switching to grid")
def transferToGenerator (self):
if self.dbusOk:
logging.info ("switching to generator settings")
# save current values for restore when switching back to grid
try:
inputType = self.acInputTypeObj.GetValue ()
# grid input type can only be either 1 (grid) or 3 (shore)
# patch this up to prevent issues later
if inputType == 2:
logging.warning ("grid input can not be generator - setting to grid")
inputType = 1
self.DbusSettings['gridInputType'] = inputType
except:
logging.error ("dbus error AC input type not saved when switching to generator")
try:
self.DbusSettings['gridCurrentLimit'] = self.currentLimitObj.GetValue ()
except:
logging.error ("dbus error AC input current limit not saved when switching to generator")
try:
self.acInputTypeObj.SetValue (2)
except:
logging.error ("dbus error AC input type not changed when switching to generator")
try:
if self.currentLimitIsAdjustableObj.GetValue () == 1:
self.currentLimitObj.SetValue (wrap_dbus_value (self.DbusSettings['generatorCurrentLimit']))
else:
logging.warning ("Input current limit not adjustable - not changed")
except:
logging.error ("dbus error AC input current limit not changed when switching to generator")
def background (self):
##startTime = time.time()
self.updateTransferSwitchState ()
self.getVeBusObjects ()
# skip processing if any dbus paramters were not initialized properly
if self.dbusOk and self.transferSwitchActive:
# process transfer switch state change
if self.lastOnGenerator != None and self.onGenerator != self.lastOnGenerator:
if self.onGenerator:
self.transferToGenerator ()
else:
self.transferToGrid ()
self.lastOnGenerator = self.onGenerator
elif self.onGenerator:
self.transferToGrid ()
# update main VE.Bus RemoteGeneratorSelected which is used to enable grid charging
# if renewable energy is turned on
if not self.dbusOk or not self.onGenerator:
newRemoteGeneratorSelectedLocalValue = 0
else:
newRemoteGeneratorSelectedLocalValue = 1
if self.remoteGeneratorSelectedItem == None:
self.remoteGeneratorSelectedLocalValue = -1
elif newRemoteGeneratorSelectedLocalValue != self.remoteGeneratorSelectedLocalValue:
try:
self.remoteGeneratorSelectedItem.SetValue (wrap_dbus_value (newRemoteGeneratorSelectedLocalValue))
except:
logging.error ("could not set /Ac/Control/RemoteGeneratorSelected")
pass
self.remoteGeneratorSelectedLocalValue = newRemoteGeneratorSelectedLocalValue
##stopTime = time.time()
##print ("#### background time %0.3f" % (stopTime - startTime))
return True
def __init__(self):
self.theBus = dbus.SystemBus()
self.onGenerator = False
self.veBusService = ""
self.lastVeBusService = ""
self.acInputTypeObj = None
self.numberOfAcInputs = 0
self.currentLimitObj = None
self.currentLimitIsAdjustableObj = None
self.remoteGeneratorSelectedItem = None
self.remoteGeneratorSelectedLocalValue = -1
self.transferSwitchStateObj = None
self.transferSwitchNameObj = None # New attribute to store the D-Bus object for CustomName
self.extTransferDigInputName = "transfer switch" # Changed to just 'transfer switch' as the key phrase
self.lastOnGenerator = None
self.transferSwitchActive = False
self.dbusOk = False
self.transferSwitchLocation = 0
self.tsInputSearchDelay = 99 # allow search to occur immediately
self.firstSearchDone = False # New attribute to track the initial search status
self.veBusFoundInitially = False
self.loggedVeBusInitialNotFound = False
# create / attach local settings
settingsList = {
'gridCurrentLimit': [ '/Settings/TransferSwitch/GridCurrentLimit', 0.0, 0.0, 0.0 ],
'generatorCurrentLimit': [ '/Settings/TransferSwitch/GeneratorCurrentLimit', 0.0, 0.0, 0.0 ],
'gridInputType': [ '/Settings/TransferSwitch/GridType', 0, 0, 0 ],
'stopWhenAcAvaiable': [ '/Settings/TransferSwitch/StopWhenAcAvailable', 0, 0, 0 ],
'stopWhenAcAvaiableFp': [ '/Settings/TransferSwitch/StopWhenAcAvailableFp', 0, 0, 0 ],
'transferSwitchOnAc2': [ '/Settings/TransferSwitch/TransferSwitchOnAc2', 0, 0, 0 ],
}
self.DbusSettings = SettingsDevice(bus=self.theBus, supportedSettings=settingsList,
timeout = 10, eventCallback=None )
# grid input type should be either 1 (grid) or 3 (shore)
# patch this up to prevent issues later
if self.DbusSettings['gridInputType'] == 2:
logging.warning ("grid input type was generator - resetting to grid")
self.DbusSettings['gridInputType'] = 1
GLib.timeout_add (1000, self.background)
return None
def main():
from dbus.mainloop.glib import DBusGMainLoop
# Configure logging to console only with default format
#logging.basicConfig(level=logging.INFO)
# Have a mainloop, so we can send/receive asynchronous calls to and from dbus
DBusGMainLoop(set_as_default=True)
# Logging start message without version
logging.info (">>>>>>>>>>>>>>>> Transfer Switch Monitor starting <<<<<<<<<<<<<<<<")
Monitor ()
mainloop = GLib.MainLoop()
mainloop.run()
main()