The following will give a false positive for multiple drivers on `signal_xyz`. The linter doesn't consider the signal index. ``` process(...) begin ... signal_xyz(0) <= ... ... end process; process(...) begin ... signal_xyz(1) <= ... ... end process; ```
The following will give a false positive for multiple drivers on
signal_xyz. The linter doesn't consider the signal index.