Transfered from Bugzilla https://sccn.ucsd.edu/bugzilla/show_bug.cgi?id=1963
Filter order (filter length - 1) is computed automatically (no value in GUI or also CLI) the transition band width is computed before it is checked whether filter order is actually even (mandatory). In case not, it is rounded up to the next even integer. Thus, true transition band width is minimally smaller than expected.
Documentation inconsistent with function behavior - switch high pass and low pass parameters
Transfered from Bugzilla https://sccn.ucsd.edu/bugzilla/show_bug.cgi?id=1963
Filter order (filter length - 1) is computed automatically (no value in GUI or also CLI) the transition band width is computed before it is checked whether filter order is actually even (mandatory). In case not, it is rounded up to the next even integer. Thus, true transition band width is minimally smaller than expected.
Documentation inconsistent with function behavior - switch high pass and low pass parameters