diff --git a/images/innr/1166-0336-191E3685_8008e8.ota b/images/innr/1166-0336-191E3685_8008e8.ota new file mode 100644 index 0000000..7ab8a49 Binary files /dev/null and b/images/innr/1166-0336-191E3685_8008e8.ota differ diff --git a/images/innr/1166-0336-191E3685_8008e8.ota.yaml b/images/innr/1166-0336-191E3685_8008e8.ota.yaml new file mode 100644 index 0000000..851ada3 --- /dev/null +++ b/images/innr/1166-0336-191E3685_8008e8.ota.yaml @@ -0,0 +1,42 @@ +# OTA metadata +file_name: 1166-0336-191E3685_8008e8.ota +source_file_name: 1166-0336-191e3685-sp244v2-1.9.30.ota +source_url: https://github.com/user-attachments/files/24494598/1166-0336-191e3685-sp244v2-1.9.30.zip +pull_request: 22 +release_notes: |- + This updates the Innr SP 244 v2 smart plug to firmware version 1.9.30. + + **Note:** Please reload ZHA or restart Home Assistant shortly after this update is fully applied to avoid an incorrectly increased "summation delivered" state. + + **Note:** The relay may turn on or off during the upgrade process. + + **Changes compared to version 1.7.23 and older** + - Fixed attribute reporting failing after power-cycle + - Improved default attribute reporting settings + - Improved thresholds for the resettable voltage and current overload protection + - Added possibility to disable voltage overload protection + - kWh in 3 decimals instead of 2 + - Added Multiplier and Divisor for kWh + - Various bug fixes and performance improvements + + **Disabling voltage overload protection** + + To disable voltage overload protection: + 1. Keep the button pressed between 15 and 20 seconds, then release + 2. After 5 seconds, the LED will start quick-blinking; keep the button pressed + 3. After 10 seconds, blinking stops; keep the button pressed + 4. After 15 seconds, the LED will start quick-blinking again + 5. Release the button. The LED will slow-blink 3 times to indicate success + + Enable again in the same way. + + Enabled/disabled state is persisted over power-cycles, even if not connected to a bridge. + While voltage overload protection is disabled, every on/off action will double-blink the LED before assuming final state. + + Current overload protection cannot be disabled. + + **Overload behavior** + + - If the voltage or current overload protection triggers, the plug switches off and fast-blinks its LED + - If the cause was voltage overload, the plug will go back to normal operation automatically when the overload condition disappears + - If the cause was current overload, the plug will stay off and in overload condition until manually operated, either with the button or by power-cycling