80 changes: 80 additions & 0 deletions docs/learn/devices/epics-put-completion.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,80 @@
---
related:
- title: set() vs put() in ophyd
url: learn/devices/set-vs-put.md
- title: EPICS Signal Variants
url: learn/devices/epics-signals.md
---

# EPICS put completion

`EpicsSignal` supports EPICS put completion, which means EPICS reports back when the write request itself has completed.

This is an EPICS-specific detail that matters because it changes how `set()` decides that a write is finished.

## Configuring `put_complete`

The relevant option is `put_complete`, which is configured on the signal definition. The default value is `False`.

```python
from ophyd import Component as Cpt, Device, EpicsSignal


class MyDevice(Device):
my_signal = Cpt(EpicsSignal, "PV:NAME", put_complete=True)
```

## How it changes `set()`

For `EpicsSignal.set()`, `put_complete` changes the completion condition:

<table>
<colgroup>
<col style="width: 22%;">
<col style="width: 48%;">
<col style="width: 30%;">
</colgroup>
<thead>
<tr>
<th>Configuration</th>
<th>Completion behavior</th>
<th>What the caller gets</th>
</tr>
</thead>
<tbody>
<tr>
<td><code>put_complete=False</code></td>
<td><code>set()</code> writes the value, then waits until the readback reaches the target.</td>
<td>A <code>Status</code> that completes when the readback matches.</td>
</tr>
<tr>
<td><code>put_complete=True</code></td>
<td><code>set()</code> calls <code>put(..., use_complete=True)</code> internally and finishes when EPICS reports put completion.</td>
<td>A <code>Status</code> that completes on EPICS put completion.</td>
</tr>
</tbody>
</table>

!!! info "How `put_complete` changes `set()`"
- `put_complete=False`: "wait until the signal value reaches the requested target"
- `put_complete=True`: "wait until EPICS says the write request has completed"

This can be useful for EPICS signals where the EPICS put-completion callback is the right completion signal for the write.

## What it does not change

`put_complete` changes how `set()` finishes, but it does not change the role of `put()`.

Even when `put_complete=True` is enabled on the signal:

- `put()` still performs a direct write
- `put()` still returns immediately
- `put()` still does not return a `Status`

That is why `set()` remains the normal ophyd API when the caller needs structured completion tracking.

!!! info "What to remember"
- `put_complete` is an `EpicsSignal` option that changes how `set()` decides the write is finished.
- With `put_complete=False`, `set()` waits for the readback to reach the target.
- With `put_complete=True`, `set()` finishes when EPICS reports put completion.
- `put_complete` does not turn `put()` into a completion-tracked API: `put()` still writes directly and returns immediately.
110 changes: 110 additions & 0 deletions docs/learn/devices/set-vs-put.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,110 @@
---
related:
- title: Introduction to ophyd
url: learn/devices/introduction-to-ophyd.md
- title: Change Config Signals from the BEC IPython Client
url: how-to/devices/change-config-signals-from-the-bec-ipython-client.md
- title: EPICS put completion
url: learn/devices/epics-put-completion.md
---

# `set()` vs `put()` in `ophyd`

In ophyd, both `set()` and `put()` can write a new value to a writable signal, but they serve different purposes.

The short version is:

- use `put()` for a direct low-level write
- use `set()` when you want a write operation with completion tracking

That distinction matters in BEC because user-facing device operations often need clear completion semantics, while device-internal helper signals often just need to publish a new value immediately.

## What `put()` does

`put()` is the low-level write method on a signal.

It sends a value to the signal and returns immediately. It does not return a `Status` object and is therefore not the right abstraction when the caller needs to wait for completion in a structured way.

`put()` is a direct wrapper around the underlying control layer, i.e. in the case of pyepics (default for ophyd_devices), it is calling `epics.PV.put()`.

Typical uses of `put()` include:

- updating a soft signal inside device implementation code
- writing trigger-like signals that should be pushed directly
- direct signal writes where completion tracking is not needed or not meaningful

Example:

```python
my_signal.put(5)
```

## What `set()` does

`set()` is the higher-level write method.

It starts a write operation and returns a `Status` object that tells the caller when the operation is considered complete or has failed. This makes `set()` a better fit for coordinated device actions, plans, and user-facing control flows.

Example:

```python
status = my_signal.set(5)
status.wait()
```

In other words, `set()` is not just about sending a value. It is about sending a value and giving the caller a standard way to observe completion.
Under the hood, `set()` uses `put()` to perform the actual write, but it adds the completion tracking layer on top.

## The practical difference

The key difference is the API contract:

<table>
<colgroup>
<col style="width: 20%;">
<col style="width: 80%;">
</colgroup>
<thead>
<tr>
<th>Method</th>
<th>Behavior</th>
</tr>
</thead>
<tbody>
<tr>
<td style="white-space: nowrap;"><code>put()</code></td>
<td>Perform a direct write. No <code>Status</code> object is returned.</td>
</tr>
<tr>
<td style="white-space: nowrap;"><code>set()</code></td>
<td>Perform a write operation with completion tracking and return a <code>Status</code>.</td>
</tr>
</tbody>
</table>

That means the choice is usually driven by what the caller needs:

- If you only need to publish or write a value, `put()` is often enough.
- If the caller needs to wait until the operation is done, use `set()`.

## How `set()` decides it is done

For a basic ophyd `Signal`, `set()` uses the lower-level write path and then waits until the signal readback reaches the target value within the configured tolerances.

This is why `set()` is often described as a write-and-wait operation rather than just a write.

For `EpicsSignal`, there is one extra detail worth knowing: `put_complete` changes how `set()` decides that the write has finished. That EPICS-specific behavior is covered separately in [EPICS put completion](../../learn/devices/epics-put-completion.md).


## Choosing between them

In practice, the choice is simple:

- use `put()` when you only need to write a value
- use `set()` when the caller needs a `Status` and clear completion semantics

!!! info "What to remember"
- `put()` is the low-level write method for directly updating a signal value.
- `set()` is the higher-level write method that returns a `Status` so callers can wait for completion.
- For a basic ophyd `Signal`, `set()` writes the value and waits until the readback reaches the target.
- If you are working with `EpicsSignal`, `put_complete` adds EPICS-specific completion behavior for `set()`.
2 changes: 2 additions & 0 deletions zensical.toml
Original file line number Diff line number Diff line change
Expand Up @@ -118,10 +118,12 @@ nav = [
{ "Managing YAML Configs" = "learn/devices/managing-yaml-configs.md" },
{ "EPICS Motor Variants" = "learn/devices/epics-motors.md" },
{ "EPICS Signal Variants" = "learn/devices/epics-signals.md" },
{ "set() vs put()" = "learn/devices/set-vs-put.md" },
] },
{ "Development" = [
{ "Pseudo Positioners" = "learn/devices/pseudo-positioners.md" },
{ "BEC Signals" = "learn/devices/bec-signals.md" },
{ "EPICS put completion" = "learn/devices/epics-put-completion.md" },
{ "Simulated Devices" = "learn/devices/simulated-devices.md" },
] },
] },
Expand Down
Loading