Binary file added images/innr/1166-0336-191E3685_8008e8.ota
Binary file not shown.
42 changes: 42 additions & 0 deletions images/innr/1166-0336-191E3685_8008e8.ota.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,42 @@
# OTA metadata
file_name: 1166-0336-191E3685_8008e8.ota
source_file_name: 1166-0336-191e3685-sp244v2-1.9.30.ota
source_url: https://github.com/user-attachments/files/24494598/1166-0336-191e3685-sp244v2-1.9.30.zip
pull_request: 22
release_notes: |-
This updates the Innr SP 244 v2 smart plug to firmware version 1.9.30.

**Note:** Please reload ZHA or restart Home Assistant shortly after this update is fully applied to avoid an incorrectly increased "summation delivered" state.

**Note:** The relay may turn on or off during the upgrade process.

**Changes compared to version 1.7.23 and older**
- Fixed attribute reporting failing after power-cycle
- Improved default attribute reporting settings
- Improved thresholds for the resettable voltage and current overload protection
- Added possibility to disable voltage overload protection
- kWh in 3 decimals instead of 2
- Added Multiplier and Divisor for kWh
- Various bug fixes and performance improvements

**Disabling voltage overload protection**

To disable voltage overload protection:
1. Keep the button pressed between 15 and 20 seconds, then release
2. After 5 seconds, the LED will start quick-blinking; keep the button pressed
3. After 10 seconds, blinking stops; keep the button pressed
4. After 15 seconds, the LED will start quick-blinking again
5. Release the button. The LED will slow-blink 3 times to indicate success

Enable again in the same way.

Enabled/disabled state is persisted over power-cycles, even if not connected to a bridge.
While voltage overload protection is disabled, every on/off action will double-blink the LED before assuming final state.

Current overload protection cannot be disabled.

**Overload behavior**

- If the voltage or current overload protection triggers, the plug switches off and fast-blinks its LED
- If the cause was voltage overload, the plug will go back to normal operation automatically when the overload condition disappears
- If the cause was current overload, the plug will stay off and in overload condition until manually operated, either with the button or by power-cycling